Thermal Energy in Buildings and the Environment

Where the heat in a heated house actually goes, what an R-value is measuring, why a brick building stays cool, and how a heat pump delivers more heat than the electricity it consumes.

7 min read10 practice questionsAsk AI about this →

Key things to remember

  1. 1Air leakage is usually the single largest heat-loss path in an older house, ahead of walls, roof, windows and basement.
  2. 2Insulation works by trapping still air in pockets small enough to stop convection currents forming.
  3. 3R-value measures resistance to heat flow, so a larger value means slower loss, and the layers in an assembly add.
  4. 4Heat escapes by the path of least resistance, so the weakest element sets the loss — upgrade that one first.
  5. 5Double glazing blocks conduction with a low-conductivity gas, convection with a narrow gap, and radiation with a low-emissivity coating.
  6. 6Thermal mass is a large product, so gives a small for a large . It flattens temperature swings; it does not reduce the total heat flow.
  7. 7A heat pump moves existing thermal energy rather than generating it, so its coefficient of performance — heat delivered over electricity used — is typically 2 to 4.
  8. 8, the unit electricity is billed in.

A heated house in an Ontario January is a bucket with holes in it. The furnace or heat pump pours thermal energy in; conduction, convection and radiation carry it back out through every square metre of the building envelope. The indoor temperature holds steady only while those two rates match, which means the heating bill is not really a measure of how warm the house is — it is a measure of how fast the house leaks. Everything in this topic is and the three transfer mechanisms, applied to a building instead of a beaker.

Where the heat escapes

Where the heat actually leaves a house.Roof 25%Walls 35%Windows 20%Air leakage 20% — gaps at sills, eaves and around doorsRoof25%Walls35%Windows20%Air leakage20%R-value: resistance to heat flowHigher R means slower conduction.Attic R-50 · walls R-22 · window R-3Heat always flows from warm to cold — insulation slows that flow, it never stops it.
Fig 1The paths by which a heated house loses thermal energy on a cold day.
Path outRough share of the lossDominant mechanism
Air leakage — gaps around doors, windows, vents and the attic hatch25–35%Convection: warm air simply leaves and cold air replaces it
Walls20–30%Conduction through the studs and the cavity
Roof and attic20–25%Conduction upward, fed by warm air rising to the ceiling
Windows and doors10–25%Conduction through the glass, plus radiation to the cold sky
Basement walls and floor slab10–20%Conduction into ground that stays near
Typical shares for an older detached house. The exact split varies, but the ranking rarely does.

Two things in that table surprise people. The first is that air leakage usually beats every solid surface — a house can be beautifully insulated and still bleed heat through a finger-width gap at the top of the wall. The second is that the roof matters more than its area suggests, because convection inside the house delivers the warmest air straight to the ceiling, so the temperature difference driving conduction is largest exactly where you would least like it to be.

Conductionparticle collisions through a ma…a metal spoon in soupConvectionwarm fluid rises and carries ene…a radiator warming a roomvacuumRadiationinfrared waves — needs no mediumsunlight crossing spaceOnly radiation crosses a vacuum, which is how the Sun's energy reaches Earth.
Fig 2The same three mechanisms from the last topic, now working against you in every exterior surface.

Insulation and R-value

Insulation works by trapping air. Still air is a poor conductor, so a material that holds millions of tiny pockets of it — glass-fibre batt, blown cellulose, rigid foam — blocks conduction, and keeping the pockets small stops convection currents forming inside them. The performance of a layer is quoted as its R-value, which is a measure of resistance to heat flow. A bigger number means heat escapes more slowly, and the values of the layers in a wall add together.

Building elementRSI (metric, )R-value (imperial)Comment
Single pane of glass0.16R-0.9Barely better than a hole with a pane over it
Double glazing, argon filled0.5R-3Roughly three times the resistance of a single pane
Triple glazing with a low-emissivity coating0.9R-5Standard in new Ontario construction
glass-fibre batt in a wall cavity3.5R-20A common Ontario wall requirement
of blown cellulose in an attic8.8R-50Attics get the most, because that is where the loss is
of solid brick0.08R-0.5Brick is thermal mass, not insulation
R-value measures resistance, so bigger is better
Heat flow through a layer is proportional to the temperature difference across it and inversely proportional to its R-value. Doubling the R-value of the attic roughly halves the rate at which energy escapes through the attic — nothing else. That is the second half of the rule: heat leaves by whichever path resists it least, so a superb wall does nothing for you while the attic hatch is bare. Upgrade the weakest path first.

Why double glazing works

A sealed double-glazed unit is two panes with a gap of roughly between them, and it attacks all three transfer mechanisms at once. The gap is filled with still air or, better, argon, which conducts heat far more poorly than glass — that blocks conduction. The gap is deliberately narrow, so the trapped gas cannot set up a circulating current between the warm pane and the cold one — that blocks convection. And one inner surface carries a microscopically thin low-emissivity coating, a metallic film that is transparent to visible light but reflects infrared back into the room — that blocks radiation. Triple glazing simply repeats the trick with a second gap.

The gap has to be the right width
Too narrow and the two panes conduct to each other almost as if they were touching. Too wide — beyond about twenty millimetres — and the gas inside is free to circulate, rising against the warm pane and sinking against the cold one, which carries energy across by convection and undoes the benefit. This is why you cannot improve a window simply by spacing the panes further apart.

Thermal mass

Walk into an old brick school or a stone church on a hot July afternoon and it feels cool. That is thermal mass, and it is a direct consequence of . Brick, concrete and stone have a middling specific heat capacity of roughly 840\ \text{J/{(kg}\cdot^\circ\text{C)}}, but a masonry wall has an enormous . The product is therefore huge, so an enormous has to flow in before is anything worth noticing. The building absorbs the afternoon's heat with barely any temperature rise and releases it again through the cool of the night.

Thermal mass is not insulation
They do different jobs and are easily confused. Insulation has a high R-value and slows the rate at which energy crosses a surface. Thermal mass has a large value of the product of mass and specific heat capacity, and it slows and flattens temperature swings without reducing the total flow at all. A solid brick wall with no insulation is excellent mass and a poor barrier, which is why heritage buildings are usually insulated on the inside face and the brick left where it is.

Heat pumps move heat rather than making it

An electric baseboard heater turns essentially every joule of electricity into a joule of heat in the room, so by the definition of efficiency it scores 100% and cannot be beaten. A heat pump beats it anyway, because it is not trying to make heat at all — it is a refrigerator running backwards. A fluid is expanded until it is colder than the outdoor air, so heat flows into it from outside; it is then pumped indoors, compressed until it is hotter than the room, and gives that heat up. The electricity runs the pump, not a heating element.

The coefficient of performance. Same shape as an efficiency calculation, but routinely between 2 and 4 rather than below 1.

A coefficient of performance of means three joules of heat delivered indoors for every joule of electricity bought. No law of conservation is broken: two of those three joules were already present in the outdoor air and were merely carried inside. The number falls as the outdoor temperature drops, because there is less thermal energy available to harvest and the pump has a larger temperature gap to work across — which is why a cold-climate model rated to operate down to about matters in Ontario, and why many installations keep a backup heat source for the coldest nights.

From joules to the bill and the emissions

Household energy is billed in convenient units rather than joules. Electricity is sold by the kilowatt-hour, where ; natural gas is sold by the cubic metre, each of which releases roughly when burnt. The environmental difference between them is decided by what is behind the meter. Burning gas in a furnace emits carbon dioxide at the house, every time. Ontario's electricity grid is largely nuclear and hydroelectric and is among the lowest-emitting in North America, so a joule of heat delivered by a heat pump carries a small fraction of the emissions of the same joule delivered by a gas furnace — and every joule the building never loses in the first place, because someone insulated the attic, carries none at all.

Worked examples

Reveal one step at a time and try to beat it to the next line.

Example 1
The interior masonry of a gymnasium has a mass of and a specific heat capacity of 840\ \text{J/{(kg}\cdot^\circ\text{C)}}. How much energy must it absorb to warm by , and what does that mean for the room?
Example 2
A hot-water tank holds of water and heats it from to . Find the energy needed in joules and in kilowatt-hours. Take c = 4180\ \text{J/{(kg}\cdot^\circ\text{C)}}.
Example 3
A cold-climate heat pump draws of electrical power and delivers heat to a house at . Find its coefficient of performance, and compare the electricity needed to deliver of heat with that needed by an electric baseboard heater.

Where marks get lost

  • Treating R-value as a measure of how much heat gets through. It measures resistance, so a higher R means less heat flow, not more.
  • Insulating one element and expecting the whole house to improve in proportion. Heat leaves by the weakest path, so a leaky attic hatch undoes an excellent wall.
  • Confusing thermal mass with insulation. A masonry wall stores a great deal of energy per degree but conducts readily — it flattens temperature swings rather than stopping heat flow.
  • Saying a heat pump breaks conservation of energy because it is 'more than 100% efficient'. It moves existing thermal energy from outdoors to indoors; it does not create any.
  • Using grams in when is quoted per kilogram — a factor of one thousand, which for a building is the difference between a kettle and a furnace.

Flashcards 9

R-value
How does insulation actually work?
Biggest heat-loss path in a typical older house
Why does double glazing work?
+ 5 more

Practice

1
What does a higher R-value tell you about a building material?
2
A concrete floor slab of mass and c = 840\ \text{J/{(kg}\cdot^\circ\text{C)}} warms by . How much energy has it absorbed, in joules?
J
3
Why is the gap in a double-glazed unit kept to roughly rather than being made much wider?
4
A heat pump delivers of heat to a house while drawing of electrical power. What is its coefficient of performance?
5
A heat pump is sometimes described as being 'more than 100% efficient'. Why does this not violate the law of conservation of energy?
6
Which heat-loss path is typically the largest in an older detached house?
7
How many kilowatt-hours is ?
kWh
8
An old brick school stays noticeably cool through a hot afternoon. What is the physics behind this?
9
Order these upgrades from the one that usually saves the most energy in an older Ontario house to the one that usually saves the least.
  1. 1Adding blown insulation to bring the attic up to R-50
  2. 2Replacing double-glazed windows with triple-glazed units
  3. 3Insulating the exterior walls during a renovation
  4. 4Sealing air leaks around the attic hatch, vents and window frames
10
Match each building feature to the mechanism it is designed to fight.
Weatherstripping around a door
Glass-fibre batt in a wall cavity
Low-emissivity coating on glass
Argon fill between two panes