Skip to content
Study Hall
Lesson 6 of 6Chemical Systems and Equilibrium
Unit 4 · Lesson 6 of 6

Measuring K in the Lab

How equilibrium constants are measured: Keq for the iron(III) thiocyanate equilibrium by colorimetry with Beer's law, a calibration curve and an ICE table; Ksp of calcium hydroxide by titration; Ka of acetic acid from pH; testing Le Chatelier predictions with FeSCN²⁺ and cobalt chloride; and analyzing experimental error.

5 min read11 practice questionsInteractiveAsk AI about this →

Key things to remember

  1. 1Beer's law: ; a calibration curve of A against c for standards has slope .
  2. 2FeSCN²⁺ standards use a large excess of so nearly all is converted; test mixtures plus an ICE table give K.
  3. 3Ksp of : titrate filtered saturated solution with HCl; and .
  4. 4Ka from pH: , ; at half-equivalence .
  5. 5Cobalt chloride: pink [\text{Co{(H}_2\text{O)}}_6]^{2+} ⇌ blue ; added or heat turns it blue (forward reaction endothermic).
  6. 6Percent error ; look for the direction of systematic errors.

Every K value in a data table was once measured by someone in a lab. The challenge is that you cannot count dissolved ions directly, and removing a sample to analyze it may disturb the very equilibrium you are trying to measure. The solution is to measure a property that tracks one concentration without changing it: the intensity of a colour, the pH, or the amount of acid needed to neutralize a filtered solution. Once you know one equilibrium concentration, the balanced equation and an ICE table give you all the others, and K follows. This lesson walks through the three classic SCH4U investigations, then shows how to test Le Chatelier's predictions and how to judge the quality of your results.

Keq of FeSCN²⁺ by colorimetry

Pale yellow iron(III) and colourless thiocyanate form blood-red FeSCN²⁺. Beer's law links its absorbance to its concentration.

Only is strongly coloured, so the colour intensity measures its concentration. A colorimeter or spectrophotometer shines light of the wavelength the complex absorbs most (blue light, about 450 to 470 nm) through a cuvette and reports absorbance, A. Beer's law states that , where is the molar absorptivity (a constant for that substance and wavelength, in L/(mol·cm)), b is the path length (usually 1.00 cm) and c is the concentration. To find , you make standards in which is known. The trick is Le Chatelier's principle: mix a small, known amount of with a large excess of , so the equilibrium is pushed so far right that essentially all the thiocyanate becomes . A graph of absorbance against concentration for the standards is a straight line through the origin, the calibration curve, whose slope is . Then you prepare test mixtures with similar amounts of both ions, measure their absorbance, read at equilibrium from the calibration line, and use an ICE table to find the other two concentrations. If several mixtures with different starting amounts all give about the same K, you have evidence for the equilibrium law itself.

StepWhat you doWhy
Prepare solutionsDissolve \text{Fe{(NO}_3)}_3 in dilute nitric acidThe acid stops from forming coloured hydroxide complexes that would add absorbance
BlankZero the colorimeter with a cuvette of the solventSo the reading counts only light absorbed by the complex
StandardsLarge excess + small known ; measure ANearly complete conversion means equals the added
CalibrationPlot A against ; find the slopeThe slope is , used to convert any absorbance to concentration
Test mixturesMix comparable amounts; account for dilution; measure AGives for the ICE table
Keep the temperature constant throughout: K changes with temperature, so readings taken at different temperatures cannot be combined.
Loading interactive…
Change concentrations and temperature and watch how the equilibrium mixture responds, as you would when testing stresses on the FeSCN²⁺ system.

Ksp of calcium hydroxide by titration

Stir excess solid calcium hydroxide in distilled water at a recorded temperature until the solution is saturated, then filter it so that no undissolved solid reaches the flask, since any solid would neutralize extra acid. Pipette 25.00 mL of the clear filtrate and titrate it with standardized HCl using phenolphthalein or bromothymol blue. At the endpoint, moles of HCl equal moles of , which gives . Each formula unit releases one and two , so and . Keep the solutions covered: carbon dioxide from the air reacts with hydroxide to form calcium carbonate, lowering . Accepted values are about at 25 °C.

Ka of acetic acid from pH

Calibrate a pH meter with buffers of known pH, then measure the pH of an acetic acid solution of known concentration, for example 0.100 mol/L. The pH gives , which equals at equilibrium, and the acid that remains is the initial concentration minus that amount. Substituting into gives Ka. Notice the significant figures: a pH reported to two decimal places gives to only two significant figures. A second method uses a titration curve: at the half-equivalence point, half the acid has become its conjugate base, so and .

Testing Le Chatelier predictions

SystemStressObservationExplanation
Add \text{Fe{(NO}_3)}_3 or KSCNDeeper redAdded reactant: Q < K, shifts right
SameAdd Paler; white precipitate removes as solid AgSCN, so it shifts left
SameAdd PalerPhosphate ties up in a colourless complex, so it shifts left
[\text{Co{(H}_2\text{O)}}_6]^{2+} (pink) (blue) Add concentrated HClTurns blueAdded shifts right
SameAdd waterTurns pinkWater is a product here, so it shifts left
SameHeat, then cool in iceBlue when hot, pink when coldThe forward reaction is endothermic, so heating shifts right and increases K
Write each prediction before mixing, then record whether the observation confirms it. A test tube of the original mixture kept aside gives a colour reference.

Error analysis

  • Fingerprints, scratches or bubbles on a cuvette scatter light, so A reads high, is overestimated and K comes out too high. Handle cuvettes by the frosted sides.
  • Incomplete conversion in the standards: if some stays unreacted, the true is lower than assumed, so the slope () is too small and every later concentration too large.
  • Undissolved solid in the Ca(OH)₂ filtrate neutralizes extra acid, so and Ksp are too high; absorbed makes them too low.
  • An uncalibrated pH meter shifts every reading; an error of only 0.05 pH units changes by about 12%.
  • Temperature drift changes K itself, so record the temperature and compare with accepted values at that temperature.
  • Report percent error against an accepted value and look for systematic errors (all results high or all low) as well as random scatter between trials.

Worked examples

Reveal one step at a time and try to beat it to the next line.

Example 1
FeSCN²⁺ standards of 1.0, 2.0, 4.0 and 8.0 × 10⁻⁵ mol/L give absorbances of 0.046, 0.092, 0.184 and 0.368 in a 1.00 cm cuvette. Find , then the concentration of a test mixture with A = 0.217.
Example 2
The test mixture above was made from 5.00 mL of mol/L and 5.00 mL of mol/L . Its equilibrium is mol/L. Calculate K.
Example 3
A 25.00 mL sample of filtered, saturated solution requires 11.05 mL of 0.0500 mol/L HCl to reach the endpoint. Calculate Ksp and the percent error compared with an accepted value of .
Example 4
A calibrated pH meter reads 2.88 for 0.100 mol/L acetic acid. Calculate Ka and compare it with the accepted value of .

Where marks get lost

  • Forgetting to account for dilution when two solutions are mixed. Initial concentrations in the ICE table are the values after mixing.
  • Assuming the equilibrium concentration of FeSCN²⁺ in a test mixture equals the SCN⁻ added. That assumption is only valid for standards made with a large excess of Fe³⁺.
  • Using for calcium hydroxide. Each formula unit releases two , so is half of .
  • Titrating an unfiltered saturated solution. Suspended solid dissolves as acid is added, so too much acid is used and Ksp comes out too high.
  • Reporting K with more significant figures than the data allow, especially from a pH reading, which gives only as many significant figures as it has decimal places.

Flashcards 9

Beer's law
Calibration curve
Why FeSCN²⁺ standards use excess Fe³⁺
Blank
+ 5 more

Practice

1
A FeSCN²⁺ solution has an absorbance of 0.230 in a 1.00 cm cuvette, and L/(mol·cm). What is its concentration, in units of mol/L? (2 decimal places)
× 10⁻⁵ mol/L
2
At equilibrium a mixture contains , and mol/L. Calculate K. (whole number)
3
Titration of a filtered saturated solution shows mol/L. Calculate Ksp, in units of . (2 decimal places)
× 10⁻⁶
4
A 0.200 mol/L solution of a weak acid HA has a pH of 2.70. Calculate Ka, in units of . (1 decimal place)
× 10⁻⁵
5
A student measures Ka of acetic acid as . The accepted value is . What is the percent error? (whole number)
%
6
A student leaves fingerprints on the cuvette when measuring FeSCN²⁺ test mixtures, but not when measuring the standards. How does this affect the calculated K?
7
Why is the saturated calcium hydroxide solution filtered before titration?
8
A test tube of the cobalt chloride equilibrium is pink at room temperature. It is placed in hot water and turns blue. What does this show?
9
Put the steps for finding K for FeSCN²⁺ by colorimetry in order.
  1. 1Convert absorbance to [FeSCN²⁺] and use an ICE table to calculate K
  2. 2Measure the absorbance of the test mixtures
  3. 3Plot the calibration curve and find its slope
  4. 4Zero the colorimeter with a blank
  5. 5Measure the absorbance of standards made with excess Fe³⁺
10
Match each stress on Fe³⁺ + SCN⁻ ⇌ FeSCN²⁺ to the colour change.
Add KSCN
Add AgNO₃
Add Na₂HPO₄
Add Fe(NO₃)₃
11
What is the name of the law ?

Spot a mistake on this page? Let us know