Every K value in a data table was once measured by someone in a lab. The challenge is that you cannot count dissolved ions directly, and removing a sample to analyze it may disturb the very equilibrium you are trying to measure. The solution is to measure a property that tracks one concentration without changing it: the intensity of a colour, the pH, or the amount of acid needed to neutralize a filtered solution. Once you know one equilibrium concentration, the balanced equation and an ICE table give you all the others, and K follows. This lesson walks through the three classic SCH4U investigations, then shows how to test Le Chatelier's predictions and how to judge the quality of your results.
Keq of FeSCN²⁺ by colorimetry
Only is strongly coloured, so the colour intensity measures its concentration. A colorimeter or spectrophotometer shines light of the wavelength the complex absorbs most (blue light, about 450 to 470 nm) through a cuvette and reports absorbance, A. Beer's law states that , where is the molar absorptivity (a constant for that substance and wavelength, in L/(mol·cm)), b is the path length (usually 1.00 cm) and c is the concentration. To find , you make standards in which is known. The trick is Le Chatelier's principle: mix a small, known amount of with a large excess of , so the equilibrium is pushed so far right that essentially all the thiocyanate becomes . A graph of absorbance against concentration for the standards is a straight line through the origin, the calibration curve, whose slope is . Then you prepare test mixtures with similar amounts of both ions, measure their absorbance, read at equilibrium from the calibration line, and use an ICE table to find the other two concentrations. If several mixtures with different starting amounts all give about the same K, you have evidence for the equilibrium law itself.
| Step | What you do | Why |
|---|---|---|
| Prepare solutions | Dissolve \text{Fe{(NO}_3)}_3 in dilute nitric acid | The acid stops from forming coloured hydroxide complexes that would add absorbance |
| Blank | Zero the colorimeter with a cuvette of the solvent | So the reading counts only light absorbed by the complex |
| Standards | Large excess + small known ; measure A | Nearly complete conversion means equals the added |
| Calibration | Plot A against ; find the slope | The slope is , used to convert any absorbance to concentration |
| Test mixtures | Mix comparable amounts; account for dilution; measure A | Gives for the ICE table |
Ksp of calcium hydroxide by titration
Stir excess solid calcium hydroxide in distilled water at a recorded temperature until the solution is saturated, then filter it so that no undissolved solid reaches the flask, since any solid would neutralize extra acid. Pipette 25.00 mL of the clear filtrate and titrate it with standardized HCl using phenolphthalein or bromothymol blue. At the endpoint, moles of HCl equal moles of , which gives . Each formula unit releases one and two , so and . Keep the solutions covered: carbon dioxide from the air reacts with hydroxide to form calcium carbonate, lowering . Accepted values are about at 25 °C.
Ka of acetic acid from pH
Calibrate a pH meter with buffers of known pH, then measure the pH of an acetic acid solution of known concentration, for example 0.100 mol/L. The pH gives , which equals at equilibrium, and the acid that remains is the initial concentration minus that amount. Substituting into gives Ka. Notice the significant figures: a pH reported to two decimal places gives to only two significant figures. A second method uses a titration curve: at the half-equivalence point, half the acid has become its conjugate base, so and .
Testing Le Chatelier predictions
| System | Stress | Observation | Explanation |
|---|---|---|---|
| Add \text{Fe{(NO}_3)}_3 or KSCN | Deeper red | Added reactant: Q < K, shifts right | |
| Same | Add | Paler; white precipitate | removes as solid AgSCN, so it shifts left |
| Same | Add | Paler | Phosphate ties up in a colourless complex, so it shifts left |
| [\text{Co{(H}_2\text{O)}}_6]^{2+} (pink) (blue) | Add concentrated HCl | Turns blue | Added shifts right |
| Same | Add water | Turns pink | Water is a product here, so it shifts left |
| Same | Heat, then cool in ice | Blue when hot, pink when cold | The forward reaction is endothermic, so heating shifts right and increases K |
Error analysis
- Fingerprints, scratches or bubbles on a cuvette scatter light, so A reads high, is overestimated and K comes out too high. Handle cuvettes by the frosted sides.
- Incomplete conversion in the standards: if some stays unreacted, the true is lower than assumed, so the slope () is too small and every later concentration too large.
- Undissolved solid in the Ca(OH)₂ filtrate neutralizes extra acid, so and Ksp are too high; absorbed makes them too low.
- An uncalibrated pH meter shifts every reading; an error of only 0.05 pH units changes by about 12%.
- Temperature drift changes K itself, so record the temperature and compare with accepted values at that temperature.
- Report percent error against an accepted value and look for systematic errors (all results high or all low) as well as random scatter between trials.